Bk-GC1120 Gas Chromatography

BK-GC1120 Gas Chromatography

BK-GC1120 Gas Chromatography

 

Features:

★Control system: designed for monitoring and controlling the instrument via the computer.
★Column Compartment/oven with superior thermal performance, multistage (10 ramps) programmed temperature control function. (supported by “control system”)
★Advanced built-in data acquisition system , supporting real time instrument status monitoring, detection signal acquisition and PC control
★Column oven accommodates up to 3 chromatographic columns, and supports quick heat-up and rapid cool-down with automated back-door opening.
★Flexible sample introduction system: 3 sample injectors could be installed and operated simultaneously with independent temperature control.
★High sensibility and stability detector.
★2 independent and analog signals output.
★M6 software, compatible with GLP/FDA-21 CFR Part11 requirements and regulations. (electronic records and signatures)

Model#  BK-GC1120
Sample Introduction System sample injector and evaporation chamber
Column Oven Temperature range Ambient temperature +7℃ ~ 400℃  (in 1℃ increment)
Temperature accuracy  ± 0.02℃
Cooling time 400℃ to 50℃ in 8-10 min at 25℃ ambient
Programmed temperature setting 0.1℃~40℃/min (in 1℃ increment)
Program ramps 7 ramps in total (10 ramps available with control workstation)
Size (L*W*H) 284*280*241mm(inside) 340*345*281mm(outside)
Flame Ionization Detector
(FID)
Detection limit ≤3×10-12g/s (C16) 
Best test result ≤3×10-12g/s (C16)
Drift ≤6×10-13A/30min
Noise ≤5×10-14A
Linearity range ≥106
Thermal Conductivity Detector
(TCD)
Sensitivity ≥5000mV, mL/mg (C16)
Baseline noise ≤20µV
Drift ≤60µV/h
Linearity range ≥104
Flame Photometric Detector
(FPD)
Detection limit ≤8×10-13g/s(P) ; ≤8×10-11g/s(S)
Drift ≤2×10-11A/30min
Baseline noise ≤5×10-12A
Nitrogen-Phosphorus Detector
(NPD)
Detection limit

≤5×10-12g/s(N)  (Azobenzene)
≤5×10-13g/s(P)  (Malathion)

 

Optional Parts Main function
GC1120-TCD Thermal conductivity detector  
GC1120-ECD Electron capture detector
GC1120-FPD Flame photometer detector
GC1120-NPD Nitrogen phosphorous detector
Chromatographic work station External interface box + work station (not include PC)
Simulation software Imitation find chromatographic condition, emulation teaching, train and knowledge base.

 

Instrument technical index

Flexible Sample Introduction System

Up to three injectors may be installed and operated simultaneously with independent temperature control. Wide range of injectors is available to be chosen from for various applications. It is very convenient for installation and disassembly of sample injectors.

Sample Injector with Mono Packed Column/Double Packed Columns:

Several alternative sample introduction methods, including on-column sample introduction and six-way valve injection;

Adapter for injection to capillary column (0.53 mm i.d.).

Sample injector for capillary column

Special sample injector with septum purge and back-pressure valve splitting;

Special programmable split/splitless injector with solenoid valve, septum purge, back-pressure valve splitting, and standalone carrier gas and make-up gas flow;

Modified dual-packed-column sample injector for injection to capillary column by employing some connectors and back-pressure valve splitting.

Advanced Pneumatics

Carrier gas control with constant pressure valve and constant flow valve;

Air and hydrogen control with constant pressure valve and needle valve;

Flow easily adjustable through constant flow valve and needle valve with digital display;

High precision, reproducibility and reliability.

Sensitive and reliable detector

Up to three detectors (FID, TCD, ECD, etc) may be installed and operated simultaneously. Simultaneous multi-detection with detectors in series or in parallel meets the various analysis requirements.

The new FID provides higher sensitivity than ever before. It is very convenient to disassemble and clean the jet and collector. Precisely fixed emitter configuration ensures conformity of product performance;

Excellent TCD detector with high-resistance tungsten-rhenium filaments provides high sensitivity. A sensitivity of 10000 mV·mL/mg is achieved with optional amplifier circuit board. Special configuration of air heat insulation enhances the stability of TCD detector

Constant-current, pulse-modulated ECD detector sets sensitivity and current by computer.

Advanced Microcomputer Control System

With advanced control techniques, microcomputer-based temperature control system provides superior performance.

High temperature precision (± 0.5℃), high reliability, and high resistance to disturbance;

Five independent heated zones, with maximum operating temperature of 400℃;

Temperature-limit setting and overheat protection.

Instrument control is accomplished through the keypad, and the instrument offers outstanding capabilities.

Self-diagnosis;

Power-off protection;

Ten methods saving and reloading;

Two controls of external events;

Timing on/off of temperature control;

Timing program, detector status, measurement range, polarity and current setting and display;

Temperature setting values, actual values, retention time and analysis time display.

 

High-performance spacious column oven

Spacious column oven accommodating capillary column and dual packed columns and convenient for column installation;

Fast heat-up and rapid cool-down column oven with automated back-door opening (300℃ to 50℃ in 7 min);

Available for both near-ambient and above ambient temperature control;

Supports 5 oven ramps with 6 plateaus.

Gas chromatography and accessories:

Carrier Gas System + Sample Introduction System + Separation System + Temperature Control System + Detector

Carrier Gas System air source/ purification and desiccation device/ flow rate control device
Sample Introduction System sample injector
Separation System chromatographic column(packed column and capillary column)
Temperature Control System (Column Oven) constant temperature and programmed temperature
Detector FID/ TCD/ FPD/ NPD

 

Advanced Microcomputer Control System:

★Superior performance with advanced, microcomputer-based temperature control system 
★High temperature accuracy (optimum ± 0.02℃), high reliability, and anti-interference
★Self-diagnosis/ self-protection function (overheat protection, power-off protection, etc.)
★Intuitive display of timing program, detector status, measurement range, current setting, etc