Features

1. DESIGN FOR FLEXIBLE USE

Standard with 10.4' LCD touch screen, functions quickly, accessible through simple, one-touch commands.

Wizard operation to lock and unlock the transport locker.

Message alarm indicate the status of the machine.

USB port update software and firmware.

Unique power-off protection function can save all the setted configurations for sudden power outages, and allow the experiment continues when power supply is restored.

2. FAST AND UNIFORM HEATING SYSTEM

Concealed lid with constant temperature and isopiestic pressure.

Electrical controlled elevating & automatic locked platform.

Thermo block is based on improved heat pipe technology, leading to extraordinary lintra-well temperature homogeneity and maximized inter-well, inter-cycle reproducibility.

Highly efficient PID&DSP control algorithm ensures faster respond and stronger interference resistance, fast and uniform heating and heat sinking.

System can be installed in three distinct configurationsf providing unmatched flexibility and convenience.

Co-located configuration (PC control).

Standalone (PC-free) configuration (Data can be export by USB and analysis on PC).

Networked configuration (PC software automatically detect all systems in LAN and allow to remote monitoring one of experimental progress and downloading of the completed run file to the PC at your desk,one PC can max control 10 instruments).

HIGH SENSITIVE AND PRECISE OPTICAL SYSTEM

High-sensitivity and wide dynamic range of fluorescence detection system, sample dynamic range could be from 101 to 1010 copies.

Fast and precise mechanical scanning structure ensures the illumination uniformity of 96 wells, eliminate edge effects, no need for ROX calibration.

Fluorescence excitation by a high-intensity and long-life LED. Bulb Luminance will not attenuation over time, free maintenance optical system through the entire life.

Professional designed fluorescence filters realize the highly fluorescence transmittance and meanwhile minimize the fluorescence channel crosstalk.

CH1

CH2

CH3

CH4

CH5

CH6

FAM SYBR Green I

SYTO 9

Eva Green

LC Green

 

HEX

VIC

TET

JOE

 

Texas Red

ROX

 

Cy5

 

Alexa Fluor

680

 

FRET

 

TAMRA

Cy3

Gentier 96E(CH1-CH6)

Currently channels are same with Bio-rad CFX96,Qiagen RotorGene Q.

Can change FRET to TAMRA/CY3 in future, and it can be the same with all ABI qPCR, Agilent Mx3005P.

Gentier 96R(CH1-CH4)

Channels are same with Roche LightCycler 96,  Agilent Mx3000P, SLAN 96S/P.

System can be installed in three distinct configurationsf providing unmatched flexibility and convenience.

Co-located configuration (PC control).

Standalone (PC-free) configuration (Data can be export by USB and analysis on PC).

Networked configuration (PC software automatically detect all systems in LAN and allow to remote monitoring one of experimental progress and downloading of the completed run file to the PC at your desk,one PC can max control 10 instruments).

EASY-TO-USE SOFTWARE

Friendly interface and clearly functional modules design, first-time users can easily start a new experiment.

All experiment data and setting options are shown conveniently on a single interface.

Instrument Management allow you managing all the Gentiers in the WLAN.

More than thousands results can be stored in device.

USB or WLAN easily transfer experiments data anywhere you needed.

Multi-options for experiments: New, New for Existed, Open data file, Double click data file.

User can define the experiments name for documentation

User can define the data storage directory themself

Pre-installed templates can help user more easier to edit the protocals.

RUN MONITORING

All running information in one screen, intuitively and simply

User can define each model to see what they like on the screen: Real-time Fluorescence ,Heat map, Run inf。,Sample Setting, Sample info...

Run the experiment first by device, later edit the sample setting in PC, when PC connected to machine, setting upload to machine automatically.

After experiment, data download to PC automatically.

DATA ANALYSIS

Optional baseline setting: Automatic or Manual.

Multi-option analytical method for different requirements: Automatic or Manual threshold method, normalization method.

Reference Dye analysis.

DATA ANALYSIS-OTHERS

A Statistics analysis: Replicate,Gene types.

A Heating map options: Ct, Concentration, Florescence.

A LIS connectivity, can export csv, Excel and Txt format.

A Row data and results can export in Excel format.

REPORT

Unique designed universal report(Research and Clinical) can be customized according to the requirements, report review and print function help clinical documentation as needed.

QUALITY DATA

 

Specification Table

Model

BK-Gentier 96E

BK-Gentier 96R

Thermal Block     

Sample capacity(wells)

96

Reaction Volume

0-100 μL

Consumables

0.2ml 96-well Plates(unskirt);
0.2ml 8-strip tubes ,0.2ml PCR single tube

(Optical flat cap,clear,frosted,white tube)

Temperature range  

0°C-100°C

Heating/cooling method

Peltier

Max heating rate

6.1°C/sec

Average heating rate

4.5°C/sec

Max cooling rate

5.0°C/sec

Average cooling rate

2.8°C/sec

Temperature accuracy

±0.1℃

Temperature uniformity

±0.1℃

Gradient Range

1°C-40°C

1°C-40°C

Gradient block

12 row

12 row

Special temperature protocol

Gradient PCR,

Long PCR,

Touch Down PCR

Gradient PCR,

Long PCR,

Touch Down PCR

Heat Lid

Temperature range

  Room Temperature–110°C

Optical System

Excitation Source

6 LEDs

4LEDs

Detector

Photodiode

Detection Position

Excitation and scan at top

Detection method

6 channels scanning at the same time, no edge effect.

Detection time

7 seconds for 96 wells for all channels

Range of
excitation/emission wavelengths
(nm)

1.465 /510 (FAM,SYBR Green I,SYTO9,EvaGreen,LC Green)

2.527/ 563(HEX,VIC,TET,JOE)

3.580 /616 (ROX,Texas Red)

4.632/ 664( Cy5)

5.680 /730 (Alexa Fluor680)

6.465 /616 (FRET)

1.465 /510 (FAM,SYBR Green I,SYTO9,EvaGreen,LC Green)
2.527/ 563 (HEX,VIC,TET,JOE)
3.580 /616 (ROX,Texas Red)
4.632/ 664( Cy5)

Probe

Taqman Probe,

Molecular beacons probe,

Scorpion probe ,

FRET

Taqman Probe,

Molecular beacons probe,

Scorpion probe

Multiplexing

Up to 6 targets

Up to 4 targets

Fluorescence Linearity

r≥0.990

Fluorescence Dynamic Range

Adjustable

Performance

Sample Linearity

/r/≥0.999

Sample repeatability

Ct value CV≤0.5%

Sample Dynamic Range

1-1010 copies

Software Functions

Data Analysis modes

Qualitative analysis,Absolute quantification, Relative quantification,Genotyping analysis,Endpoint analysis,
Melt curve analysis, High Resolution Melting

Control modes

1.10.4' touch screen
2. PC direct control
3. WLAN control(One PC can control max 10 units, and device can be controlled by any PC in the WLAN)

Sample Drawer

Touch screen commend

Data Stroage

Upload and download through USB disk,1000 results can be stored  in machine

Power failure protection

Automatically start running experiments after power supply, no need wait PC software

Customize Report

Templates reserved ,report can customized

Administration Management

Administrator can set functions limits for users

Transport Locker

Automatically detect transport locker

Fault Management

Fault report and analysis, solution instruction

LIS connection

CSV,Excel,TXT format data output,open port for LIS connection

Others

PC operating system

Win 7, Win 10

Communication Port

 1 ethernet and 3 USB

Footprint (WxDxH)

355mm X 480mm X 485mm

Weight

30kg

Power usage

 AC 100 to 125 V / 200 to 240 V (50/60 Hz).

power consumption

900VA

Work environment

Temperature:10°C~30°C  Humidity:20%~85%