BK-GR SERIES Autoclave
BK-GR SERIES Autoclave
Heavy-gauge sterilization chamber
The heavy gauge sterilization chamber in a diameter of 40cm offers a massive space to satisfy various sterilization requirements.
Microcomputer control system
The latest ■Inspiration" fast-speed microcomputer intelligent control system is highly robust to not only realize the total-process controls of sterilization, but also enable convenient maintenance, inquiry, calibration, recording and upward scalability in the future. It allows three tiers of administrations, to guarantee satisfactory us and management of the autoclave.
Waste sterilization mode:
Dedicated waste sterilization procedures are established for effective sterilization of lab wastes.
Drying
Thoroughly drying according to the CE standard, on hot sale in the Europe
Cooling loch OPEN temperature
Each procedure can set different cooling lock OPEN temperatures according to the thermal inertia of the sterilization object so as to prevent the user from opening the cover and hence getting burnt when the sterilization object(particularly liquid) is still in an unsafe state.
Simple and easily understandable and operable control p
Preset Procedures and memory system
Six sterilization procedures and warming procedures are preset for 由e sterilizing, warming and drying of solids and liquids, the melting and warming of agars. There are up to 60 cycles and be created and saved to be readily used.
Safety
Mechanical interlocking: the unique "eight-column evenly distributed" interlocking device is safer and more reliable than common interlocking devices. The electric double inner locks enable the control system to monitor the temperature and pressure in the sterilization chamber on a real-time basis and disable opening of 由e sterilization chamber cover until the safe temperature and pressure are reached, hence guarantee the personal safety of the operator
Function Table
Feature |
GR60DR GR85DR GR110DR |
GR60DF GR85DF GR110DF |
GR60DA GR85DA GR110DA |
|
Sterilization mode |
Solid mode: Heating-Sterilizing-Exhausting and air cooling |
YES |
YES |
YES |
Solid with drying mode: Heating-Sterilizing-Exhausting and air cooling -Water drainage-drying |
YES |
NO |
NO |
|
Liquid with warming mode: Heating-Sterilizing-Precooling-Exhausitng-Warming |
YES |
YES |
YES |
|
Liquid mode: Heating-sterilizing-Precooling-Steam exhausting |
YES |
YES |
YES |
|
Waste Mode: Heating-Sterilizing-Steam exhausting and air cooling |
YES |
YES |
YES |
|
Agar Mode: Heating-Melting-Warming |
YES |
YES |
YES |
|
Automatic water feeding |
STANDARD |
STANDARD |
NO |
|
Water level sensor |
STANDARD |
STANDARD |
NO |
|
Cooling fan |
STANDARD |
STANDARD |
OPTIONAL |
|
Load thermometer |
OPTIONAL |
OPTIONAL |
OPTIONAL |
|
Printer |
OPTIONAL |
OPTIONAL |
OPTIONAL |
|
Memory system |
Create 60 procedures |
Create 60 procedures |
Create 20 procedures |
Specification Table
Opening way: flip top
Type DA: Fully automatic, cooling fan, basic model
Type DF: Automatic water feeding and fast cooling based on Type DA
Type DR: Automatic drying function based on Type DF
All models have a cooling fan.
Model |
GR60DA |
GR85DA |
GR110DA |
GR60DF |
GR85DF |
GR110DF |
|
GR60DR |
GR85DR |
GR110DR |
|
Model difference |
DA:Standard + cooling fan, DF : DA+automatic water feeding, DR: DF+drying |
||
Capacity(L) |
60 |
85 |
110 |
Dimension(L*W*H,mm) |
660x644x980( DA) |
660x644x980( DA) |
660x644xll80(DA) |
Chamber dimension(Dia*H,mm) |
ф400x505 |
ф400x700 |
ф400x895 |
Rate power supply(w) |
2900 |
4600 |
4600 |
Stainless steel basket (Dia*H,mm) |
(ф 360x200)x2 |
(ф 360x280)x2 |
(ф360x250)x3 |
Power requirement |
22OVJ6A, 50/60HZ |
||
Temperature accuracy |
0.1 °C |
||
Working environment |
5-45°C , relatively humidity 10%-85% |
||
Chamber material |
SUS 304 |
||
Sterilization temperature |
105-138°C |
||
Sterilization time range |
1-6000 minutes |
||
Melting temperature |
60-100°C |
||
Melting time range |
1-6000 minutes |
||
Warming temperature |
45-60°C |
Warming time range |
1-9999 minutes |
Drying(only for DR model) |
1-300 minutes, drying temperature 80-140°C |
Cooling lock OPEN temperature |
40-80"C for liquid cycle, 40-99°C for other cycles |
Sterilization cycle |
l.Liquid 2.Liquid with warming 3.Solid 4.hstruments packed with cloth 5.Fabric 6.Rubber 7.Fast 8.Waste 9.Agar melting lO.Self defined 11.Drying (only for drying models) |
Sterilization cycle number |
DA can save up to 20 cycles, DF/DR can save up to 60 cycles |
Exhaust mode |
Automatic internal discharging ,with a steam collecting bottle inside. Exhaust speed can be selected by 6 levels |
Lid opening way |
flip open |
Steam collector and water tank |
DA: embedded 2 steam collector, DF:embedded 2 steam collector and 28L water tank DR: embedded steam collector and 28L water tank |
Preset range of timer |
Can be preset and auto start up to 6 days in advance |
Display range of pressure gauge |
-0.1-0.5Mpa |
Pressure |
Max working pressure:0.27Mpa,design pressure:0.35Mpa |
Controller |
"Inspiration" fast speed microcomputer controller |
Safety device |
"eight column evenly distributed" interlocking device, electric double inner locks, lid closing checking, dry scorch protection, overpressure protection, safety valve, water level sensor, over temperature protection, temperature monitor, over current and short circuit protection, leakage protection, cooling lock, anti-scald chamber cover and bench, automatic troubleshooting |