Home    Lab instrments    Chromatograph    Gas Chromatograph    BK-GC1290 Gas Chromatography with 7 inch touch screen display
1695354312071

BK-GC1290 Gas Chromatography with 7 inch touch screen display

BK-GC1290 Gas Chromatography with 7 inch touch screen display

Gas Chromatography

 

Features
★ Control system: designed for monitoring and controlling the instrument via the computer.
★ Column Compartment/oven with superior thermal performance, multistage (10 ramps) programmed
temperature control function. (supported by “control system”)
★ Advanced built-in data acquisition system , supporting real time instrument status monitoring,
detection signal acquisition and PC control
★ Column oven accommodates up to 3 chromatographic columns, and supports quick heat-up and
rapid cool-down with automated back-door opening.
(400℃ to 50℃ in 6 min at 25℃ cambient)
★ Flexible sample introduction system: 3 sample injectors could be installed and operated
simultaneously with independent temperature control.
★ High sensibility and stability detector.
★ 2 independent and analog signals output.
★ Clarity software, compatible with GLP/FDA-21 CFR Part11 requirements and regulations.
(electronic records and signatures)
★ Special analyzers, like RGA, NGA, PINDA, etc. according to ASTM standards
Electronic pneumatics control system
Flow rate: 200ml/min (N2), 1000ml/min (He)
Flow rate accuracy: ±5%
Flow rate repeatability: ±0.35%
Split ratio: 0-5000(He), 0-1000(N2)
Inlet temperature: 0-420℃
Model#  BK-GC1290
Description EPC(electronic pneumatic control)
 7 inch touch screen display
Sample Introduction System sample injector and evaporation chamber
Column Oven Temperature range Ambient temperature +7℃ ~ 420℃  (in 1℃ increment)
Temperature accuracy  ± 0.02℃
Cooling time 350℃~100℃≤3min, 400℃~50℃ in 8-10 min at 25℃ ambient
Programmed temperature setting 0.1℃~80℃/min (in 1℃ increment)
Program ramps 20 ramps in total (99 ramps available with control workstation)
Size (L*W*H) 284*280*241mm(inside) 340*345*281mm(outside)
Flame Ionization Detector
(FID)
Detection limit ≤8×10-12g/s (n-hexadecane)
Drift ≤1.5×10-13A/h
Noise ≤3×10-14A
Linearity range ≥106
Flame Photometric Detector
(FPD)
Detection limit

≤8×10‐13g/s(P)

≤8×10‐11g/s(S)

Drift ≤2×10‐11A/30min
Baseline noise ≤5×10‐12A
Nitrogen-Phosphorus Detector
(NPD)
Detection limit ≤5×10-12g/s(N) (Azobenzene)
≤5×10-13g/s(P)  (Malathion)
 
Electronic pneumatics control system
Flow rate 200ml/min (N2), 1000ml/min (He)
Flow rate accuracy ±5%
Flow rate repeatability ±0.35%
Split ratio 0-5000(He), 0-1000(N2)
Inlet temperature
0-420℃
 
 
Gas chromatography and accessories:
Carrier Gas System + Sample Introduction System + Separation System + Temperature Control System + Detector
Carrier Gas System air source/ purification and desiccation device/ flow rate control device
Sample Introduction System sample injector
Separation System chromatographic column(packed column and capillary column)
Temperature Control System (Column Oven) constant temperature and programmed temperature
Detector FID/ FPD/ NPD

Advanced Microcomputer Control System

★Superior performance with advanced, microcomputer-based temperature control system 
★High temperature accuracy (optimum ± 0.02℃), high reliability, and anti-interference
★Self-diagnosis/ self-protection function (overheat protection, power-off protection, etc.)
★Intuitive display of timing program, detector status, measurement range, current setting, etc